- On the ribbon, click
Design tab
Power Transmission panel
Limits/Fits Calculator
.
- On the Conditions group box, select the basis fit system and enter the calculation conditions.
- On the Tolerance Zones area, select the Fit Type from the pull-down list (for example the Interference fit).
- From the calculation results, you can select from the different colored tolerance zones. If such a tolerance zone does not exist, the conditions entered did not find any suitable fits.
Note: Click the More in the right lower corner of the Calculation tab to specify options such as standard or displayed tolerance image.
|
Clearance Fit
The calculated value of the shaft clearance fit in the bronze bushing.
This procedure creates an example using the sample specifications.
|
- On the ribbon, click
Design tab
Power Transmission panel
Limits/Fits Calculator
.
- On the Tolerance Zones group box, select Clearance Fit from the Fit Type drop-down list.
- On the Conditions group box, select the Hole-basis system of fits option.
- Set Basic Size to 40 mm.
- Set Min. clearance to 0.02 mm.
- Set Max. clearance to 0.08 mm.
- The result is only one highlighted tolerance zone “f”.
- Click OK.
|
Interference Fit
The interference fit value of the bronze bush in the hole hub.
This procedure creates an example using the sample specifications.
|
- On the ribbon, click
Design tab
Power Transmission panel
Limits/Fits Calculator
.
- On the Tolerance Zones group box, select Interference Fit from the Fit Type drop-down list.
- On the Conditions group box, select the Hole-basis system of fits option.
- Set Basic Size to 42 mm.
- Set Min. clearance to 0.005 mm.
- Set Max. clearance to 0.05 mm.
- From the calculation results, you can select from the different colored tolerance zones. If such a tolerance zone does not exist, the conditions entered did not find any suitable fits.
- Click OK.
|
Transition Fit
The shaft and key fit are designed for easy disassembly.
This procedure creates an example using the sample specifications.
|
- On the ribbon, click
Design tab
Power Transmission panel
Limits/Fits Calculator
.
- On the Tolerance Zones group box, select Transition Fit from the Fit Type drop-down list.
- On the Conditions group box, select the Hole-basis system of fits option.
- Set Basic Size to 40 mm.
- Set Max. clearance to 0.03 mm.
- Set Max. interference to 0.022 mm.
- The result is only one highlighted tolerance zone “k”.
- Click OK.
|