For runs being saved to the ISOGEN format, lists the name and path for all tube and pipe components with incomplete ISOGEN property data. The system generated Type and ISOGEN SKEY information is listed for validation.
| Access: |
With one or more runs selected, click
Assemble tab
|
|
Tube and Pipe Components |
Lists the run components that have incomplete ISOGEN information. Click a name in the list to highlight and identify the component in the graphics window. |
|
|
Type |
Lists the system-generated type information for validation. Click the type name in the column list, and then click the arrow to select from the list if needed. |
|
|
ISOGEN SKEY |
Lists the system-generated SKEY (symbol key) information for validation. Click the SKEY character combination in the column list, and then click the arrow to select from the list if needed. If the SKEY includes wild card characters, select the value from the next drop-down list. |
|
|
<Character Keys> = |
Lists the wild card values for selected SKEYs, if appropriate. Wild card values include: |
|
|
** |
replaced by an appropriate two-character end condition. |
|
|
@ |
replaced by an integer value from 1 to 9 to denote the number of segments. |
|
|
+ |
replaced by an integer value from 1 to 9 to denote the bend radius. This integer is not used for pipe length calculations. |
|