Once the splice is placed in the harness assembly, you can add or modify property data on the pin occurrences for the splice. You cannot change splice pin names. Unique occurrence properties are stored within the assembly in which they are placed.
- In the browser, double-click the harness assembly.
- In the browser, right-click the splice pin, and then select Harness Properties from the context menu.
- In the Pin Properties dialog box, click the Custom tab to add new properties or modify existing properties.
- To add new properties, enter a Name, Type, and Value, and then click Add.
- To modify existing properties, select the property to modify, change the settings as needed, and then click Modify.
- Click Apply to continue modifying or adding properties or OK to finish.