Solver message 702615

Message text

** WARNING 702615 ** The suitability of this model to Dual Domain analysis is poor, but sufficient to perform a cool analysis. Results may be inaccurate. Analyze with 3D analysis technology for better results.

Explanation

The model may be too thick for a dual domain cool analysis. The results may be of poor quality.

Resolution

Use 3D analysis technology to analyze the part.