Solver message 98110

Message text

** WARNING 98110 ** The PVT model coefficients in the PVT properties of the currently selected material specify a material with a constant density, that is, no change in volume with pressure or temperature. The residual stress calculation can therefore not be performed.

Explanation

Based on the pvT model coefficients you have entered, the material has a constant density. Residual stress cannot be calculated for a material with constant density.

Resolution

If necessary, contact Autodesk Moldflow Plastics Labs to arrange pvT testing of the material.