** WARNING 1204070 ** It is impossible to fill the cavity by adding only one injection location. Add one injection location and run the analysis again.
After considering various gating locations within the part, the injection pressure and/or clamp force required to fill the part was found to be greater than the maximum allowed values specified in the gate location advanced options and the injection molding machine properties. The part is too thin to be filled from just one injection location with the currently selected material.