Solver message 220131

Message text

** WARNING 220131 ** Short shot detected.

Explanation

Either the temperature of the flow front dropped to the transition temperature of the material -freezing the flow front, or there was insufficient injection or packing pressure to fill the part. A short shot has occurred.

Resolution

Insufficient temperature
Increase the injection rate in the process settings.
Decrease the injection time in the process settings.
Increase the injection temperature in the process settings.
Increase the mold temperature settings in the process settings.
Select a different material.
Insufficient pressure
Increase the maximum machine pressure for the injection molding machine in the process settings.
Shorten the feed system to reduce flow length.
Increase the injection temperature in the process settings.
Select a different material.
Select a different molding machine.