Redefining nominal maximum deflection when viewing warpage results

When the Warp analysis has completed, you need to specify a reference plane for the assessment of warpage, and a nominal maximum deflection value, which is the desired maximum out-of-plane deflection in the part.

When viewing the warpage results you may need to redefine the nominal maximum deflection value.

To redefine the nominal maximum deflection value, apply the following steps.

  1. Click Warpage Constraints (Results tab > Results panel > Warpage Constraints).
  2. Click Restore default value to define the default maximum deflection, or enter a specific value in the Nominal max. deflection text box.
  3. Click Apply to recalculate the Warpage Indicator results.