This topic specifies the conditions under which an area of the Cooling quality result will appear in red.
The cooling time variance for the area is a value below -75% or above +150% of the average time to freeze for the entire part.
The Temperature variance result temperature range for the area is more than 20°C under or 20°C over the average surface temperature for the entire part.