Using the Analysis Wizard

The Analysis Wizard will step you through the analysis setup process.

It can also be used to modify the parameters of an existing analysis, such as changing the material or process settings.
Note: The available options depend on the selected analysis sequence. For example, when performing a molding window analysis you will not be able to modify the process settings since the molding window analysis does not take these into account.
  1. Click Analysis Sequence (Home tab > Molding Process Setup panel > Analysis Wizard) and select the sequence(s) you would like to run. If you haven't selected an injection location yet, then not all the analysis sequences will be available. Likewise, if you don't want to run a Gate Location analysis, then the Gate Location tab will not be activated.
  2. Click Next to move to the next active tab, or simply click on the tab you are interested in editing.
  3. Choose the material you are interesting in using from the Material tab.
  4. Edit the process settings from the Process Settings tab.
  5. You can edit the packing profile in a Fill+Pack analysis in the Advanced tab.
  6. Edit the accuracy of your results using the Accuracy tab.