Solver message 98303

Message text

** WARNING 98303 ** The polymer PVT data is incorrect. Unable to perform residual stress analysis.

Explanation

This error occurs when the solid density is less than the density calculated using the Tait 2-Domain pvT model at the transition temperature and zero pressure.

Resolution

  • Edit the current material, select the pvT Properties tab and change the value for the Solid density.
  • Edit the current material, select the pvT Properties tab and change values for the coefficients for the Tait 2-Domain pvT model.
  • Select a different material.