Solver message 302130

Explanation

The AMG matrix solver for coupled 3D flow calculations is set to On or Automatic but is only used where required. The analysis automatically uses the AMG matrix solver when it is appropriate for a specific model.

Resolution

You may turn the AMG matrix solver for coupled 3D flow calculations on or off by editing the AMG matrix solver selection option in the Solver Parameters dialog. To access this dialog, ensure you are using a 3D model.
  1. Click Analysis > Process Settings Wizard > Advanced options. The Fill+Pack Analysis Advanced Options dialog appears.
  2. From the Solver Parameters section, click Edit. The Thermoplastics injection molding solver parameters (3D) dialog appears.
  3. From the Solver Setup section, click Solver parameters. The Solver Parameters dialog appears.
  4. Select the desired setting from the AMG matrix solver selection drop-down list.