** WARNING 304470 ** No cooling stage will be added to the packing profile. The time to reach the end of the specified packing profile is greater than the (fill + pack + cool) time specified by the prior Cool analysis. The analysis will stop at the end of the specified packing profile.
A Cool analysis was run before this Fill+Pack analysis. The Cool analysis specified the total time of injection + packing + cooling. The Fill+Pack analysis specified a packing profile, which is applied after the velcoity-pressure switchover. The sum of the velocity-pressure switchover time and the packing profile time is greater than the time specified by the Cool analysis, so no additional cooling stage will be added to the end of the packing profile.
None required