Solver message 104010

Message text

** WARNING 104010 ** There is no valid CRIMS data available for this material. Uncorrected residual stress shrinkage model will be used.

Explanation

The selected shrinkage model for the current material is Corrected Residual In-Mold Stress (CRIMS), however, there are no model coefficients data available for that shrinkage model. There are also no model coefficients data available for the Residual Strain Shrinkage model so the Uncorrected Residual Stress model, which does not require shrinkage testing of the material, is used.

Resolution

  • Select a different material.
  • Select a different shrinkage model.
  • Contact Autodesk Moldflow Plastics Labs for shrinkage data for the current material.