This topic specifies the conditions under which an area of the Cooling quality result will appear in yellow.
The cooling time variance for the area is a value between -60% to -75% or +100% to +150% of the average time to cool for the entire part.
The Temperature variance result temperature range for the area is between 10 to 20 degrees C under or 10 to 20 degrees C over the average surface temperature for the entire part.