Message text
** WARNING 98015 ** The cycle time (cycle time) is greater than 500 seconds. Review the part design if this seems excessive.
Explanation
The cycle time value for the analysis is greater than 500 seconds.
Resolution
- If the cycle time is calculated by the analysis, review the part design to determine whether there is a problem, such as cooling channel layout or part thickness.
- If the cycle time is entered in the Process Settings Wizard, check the time entered to see if it is correct.