** WARNING 702620 ** Only frozen percent% of the part is frozen at the end of the cycle time. This could affect the cooling quality of the part. Increase the cycle time to ensure that the entire part is frozen at the end of the cycle time.
A Cool anlaysis has been done on the part, however at the end of the cycle time the part is not entirely frozen. This is not ideal and will show poor quality on the cooling quality plot.
Increase the cycle time if it is a manual analysis or if it is an automatic analysis raise the coolant temperatures to a value closer to the target mold temperature ensuring that the part cools more evenly.