** WARNING 1100540 ** The runner balance algorithm has determined it is physically impossible to balance the geometry with the provided target pressure.

Explanation

The Runner Balance analysis was unable to balance the runners at the target pressure specified in the process settings for one of the following reasons.
  • The cavity fill pressure is greater than the target pressure.
  • The cavity fill pressure + runner system pressure drop is greater than the target pressure.
  • The dimension constraints in the runner system do not allow the pressure drop in the runners to be reduced sufficiently.

Resolution

  • Change the process settings for the filling analysis.
  • Select a different material.
  • Increase the target pressure in the process settings.
  • Relax the constraints on the runners.
  • Change the design of the runner system.