Selecting an Analysis Sequence

You can set analysis sequences for a model in the pre-processing stage, provided that you know all of the analyses that are required.

Note: Selecting a new analysis sequence after already performing an analysis sequence invalidates any existing results. Select Create Copy from the prompt to retain the results and create a duplicate study.
  1. Ensure you have set the required molding process.
  2. Click Analysis Wizard, Home tab (Home tab > Molding Process Setup panel > Analysis Wizard)

    The Sequence page of the Analysis Wizard appears containing a list of possible analysis sequences.

  3. Select the required analysis sequence for your study.
  4. Click Finish.

The new analysis sequence is updated in the Study Tasks and Project View panes.

CAUTION:
Running a large number of analyses simultaneously requires a large amount of run-time memory, and may cause the analysis to fail.