When creating or optimizing runners, gates, cooling channels or the sprue, it is possible to select commonly used (standard) sizes for all dimensions from a list you have generated. This list can be loaded into any project for reuse as required.
- Click ().
The Standard sizes dialog appears.
- Enter a standard size in the Size text box, and then click Add.
The value will be moved to the list of standard sizes.
- Repeat previous step for each value to be added.
- Click Save.
The Save As dialog appears.
- Enter a suitable name into the File name text box, and then click Save.
The values are saved as a Standard Runner Sizes (*.srs) file.
- Click OK to save and close the dialog.
The list needs to be loaded into a project before it can be used.
Note: The standard sizes can be changed, or other values used, at any time during the modeling process.