Temperature, mold (averaged) result

The Temperature, mold (averaged) result shows the cycle averaged temperature of the entire mold, calculated using the finite element method (FEM). This result could be considered a sum of internal mold, the circuit metal and mold boundary results calculated using the boundary element method (BEM).

Using this result

Use this result to find localized hot or cold spots, and determine whether they will affect cycle time and part warpage. If there are hot or cold spots, you may need to adjust the cooling channels, or coolant temperature.

The minimum and maximum mold temperature should be within 10°C of the target temperature for amorphous materials and within 5ºC for semi-crystalline materials. This guideline may be difficult to achieve for most molds, but should be the target of the Cool analysis. The narrower the temperature variation over the mold face, the less likely the mold temperature variation will contribute to warpage and an extended cycle time.

The Temperature, mold (averaged) result will typically be between 10ºC and 30ºC above the coolant inlet temperature. Cooling channel placement and the thermal conductivity of the mold will affect the temperature variations. If an automatic Injection + Packing + Cooling time is used, a coolant temperature very close to the target temperature will significantly extend the predicted cycle time.

Things to look for

When viewing the Temperature, mold (averaged) result, watch for the following: