The Temperature, maximum, cold runner result shows the maximum temperature across the cold runner temperature profile, calculated at the end of cooling time.
This profile is based on the average mold surface temperatures for the cycle (Temperature at surface, cold runner result).
Use the Temperature, maximum, cold runner result plot to check that the polymer melt temperature is below the ejection temperature for the material at the end of cooling, so that the part can be ejected successfully.