The modified 2-domain Tait pvT model is used to determine the density of the material as a function of the temperature and pressure. This variation impacts on many aspects of the flow simulation.
The 2-domain Tait pvT model is given by the following equations:

where:
-
is the specific volume at temperature and pressure
-
is the specific volume at zero gauge pressure
-
is the temperature, in K
-
is the pressure, in Pa
-
is a constant, 0.0894
-
accounts for the pressure sensitivity of the material and is defined below.
The upper temperature region
can be described by the equations:



where:
-
,
,
,
and
(which represents the volumetric transition temperature,
, at zero gauge pressure) are data-fitted coefficients.
The lower temperature region
can be described by the equations:



where:
-
,
,
,
,
,
,
, and
are data-fitted coefficients
Note: The

value for crystalline resins only applies to temperatures below the transition temperature.
The dependence of
on pressure can be described by the equation:

where:
-
and
are data-fitted coefficients