Plumbing fixtures are often hosted components, placed on a vertical face, face, or work plane.
- In the Project Browser, open a view where you want to place a plumbing fixture.
- In the Project Browser, right-click the view, click Apply Template Properties to Current View, and select Plumbing Plan from the Apply View Template dialog.
Note: The Plumbing Plan view template is available when you create a project using the mechanical default template.
- Click Systems tabPlumbing & Piping panel, and select a particular fixture type from the Type Selector.
- On the ribbon, verify that Tag on Placement is selected to tag the plumbing fixture automatically.
- On the Options Bar, to include a tag leader, select Leader and specify the length.
- Click Place Plumbing Fixture tabPlacement panel, , or to specify a host component.
Tip: When placing a plumbing fixture on a work plane, it may be necessary to Pick a Plane in the Work plane dialog, or by selecting Placement Plane on the Options Bar when placing the fixture.
- Move the cursor to where you want to place the plumbing fixture, and click.
Tip: You can press Space to rotate the plumbing fixture prior to placing it in the view. The fixture is rotated by 90 degrees each time you press Space.