Path Reinforcement Type Properties

Note: Path Reinforcement Type properties are not available in Revit 2009 or later releases. Newly created path reinforcement instances will not have these properties. However, legacy projects maintain the properties for editing purposes. View non-legacy rebar cover reference settings in the Structural section of Instance Properties of a host. See Editing Rebar Cover.

The following table describes each parameter contained in the Path Reinforcement Type Properties dialog. Select the legacy path reinforcement and then select Modify | Structural Path Reinforcement tabProperties panel Type Properties to access this table.

Path reinforcement properties for structural walls are identified as either exterior or interior to reflect the vertical orientation of the rebar. Properties for structural floors are identified as either top or bottom to reflect the horizontal orientation.

Name Description
Construction
Rebar Cover Top/Exterior Specifies the offset from the top/exterior face of the host to the rebar.
Rebar Cover Bottom/Interior Specifies the offset from the bottom/interior face of the host to the rebar.
Rebar Cover Side/Edge Specifies the offset from the side/edge of the host to the rebar.