You can customize the appearance of panel schedules. You can specify settings for general appearance, as well as circuit information and the loads summary.
General Settings
Circuit Table
The following formatting options are available for the branch panel template type when the Two Columns, Circuits Across panel configuration is selected.
Loads by Phase: This format, available for 2-column branch panel templates only, displays each circuit on its own row.
In this option, the circuits are on individual rows, instead of displaying 2 circuits per row. Circuit 1 is in the first row, Circuit 2 is in the second row, and so on. Loads for each phase are displayed in a single column.
Display multiple rows for multi-phase circuits
Show circuit number on one row for multi-phase circuits
Loads in Split Column by Phase. The default 2-column branch panel template format. There are 2 circuits per row, and the load values are shown in one larger column that is split into two. Circuits 1 and 2 are assigned to phase A, circuits 3 and 4 are assigned to phase B, and so on.
Display multiple rows for multi-phase circuits
Show circuit number on one row for multi-phase circuits
Loads in Shared Column by Phase. This format is only available for 2-column branch panels only. In this option, the only difference from the format of Loads in Split Column by Phase (above) is that the loads for the 2 circuits on one row are separated by a slash instead of displaying in separate columns.
Circuit numbers on multiple rows
Circuit number on one row for multi-phase circuits
Mirrored Phase Columns: This format, available for two column branch panels only, features 2 sets of phase columns with 2 circuits per row. The loads for circuit 1 and circuit 2 are shown in separate phase columns, and so on.
Display multiple rows for multi-phase circuits
Show circuit number on one row for multi-phase circuits
This is an alternate method of circuiting a branch panel. Instead of the circuits being assigned across the panel, they are assigned (top to bottom) down one side and down the other side.
The following formatting options are available for the branch panel template type when the Two Columns, Circuits Down panel configuration is selected.
Loads by Phase:
Display multiple rows for multi-phase circuits
Show circuit number on one row for multi-phase circuits
Loads in Split Columns by Phase. This format features 2 circuits per row, with the load values displayed in one larger column that is separated into two.
Display multiple rows for multi-phase circuits
Show circuit number on one row for multi-phase circuits
Loads in Shared Column by Phase. This format, available for 2-column branch panels, features the loads for the two circuits on one row separated by a slash.
Display multiple rows for multi-phase circuits
Show circuit number on one row for multi-phase circuits
Mirrored Phase Columns. This format, available for two column branch panels only, features two sets of phase columns. Two circuits per row, and the load for circuit 1 and circuit 2 are shown in separate phase columns.
Display multiple rows for multi-phase circuits
Show circuit number on one row for multi-phase circuits
Total Load Only per Circuit. In the 1-column branch format shown here, the first row is the first circuit, and the second row is the second circuit.
Show circuit number on one row for multi-phase circuits
The format shown here displays a subset of the total load, and the load for that phase.
Display multiple rows for multi-phase circuits
No Load Information. This format does not display load information.
Show circuit number on one row for multi-phase circuits
Display multiple rows for multi-phase circuits
Separate Phase Loads per Circuit. If you are using the Circuit Naming by Phase settings, this format is most suitable.
Show circuit number on one row for multi-phase circuits
Display multiple rows for multi-phase circuits
For switchboards, every circuit displays a the same number regardless of the number of poles.
Separate Phase Loads per Circuit
For single phase panels, you can hide or show column for third phase
Total Load Only per Circuit
The first row is the first circuit (3-pole). The second row is the second circuit (3-pole).
Single phase options are not available
Loads Summary
Loads summary options