Solve Stage 2: Thermal-Only, Transient Phase

In the previous step, we solved the steady state flow distribution. In this step, we will solve the time-varying temperature distribution.

Click Solve from the Setup tab:

Click the Physics tab.

Flow = Off

Heat Transfer = On

Click the Control tab.

Solution Mode = Transient

Time Step Size = 5

Inner Iterations = 2

Results Output (Under Save Intervals) = 2

Continue From = s100

Time Steps to Run = 16

Click Solve to start the analysis.

These settings cause the solution to vary with time.

The time step is 5 seconds, and we are running 16 time steps, for a total of 80 seconds. This solves two complete cycles of the transient inlet temperature (period = 40 seconds).

The Results Output of 2 saves every other time step (every 10 seconds).

The number of inner iterations per time step is reduced to 2 because flow-only heat transfer is linear, and does not require the default of 10 inner iterations.

For more about running transient analyses