Properties

The fluid properties required for fluid flow and heat transfer analysis are listed in the following table.

A set of consistent units for cm and inches is shown. Other units may be used by making the appropriate conversions.

Note for inches, the values are obtained by dividing common table values of these properties by the conversion factor, gc and converting feet to inches, where gc is also defined in the table.

Symbol Description Units - cm Units - inch
Cp constant pressure specific heat Joule/gram-K Btu-inch/lbf-sec2-R
gc conversion factor 1.0 gram-cm/sec2-dyne 386.4 lbm-inch/lbf-sec2
k thermal conductivity Watt/cm-K Btu/sec-inch-R
compressibility (ratio of specific heats for gases and bulk modulus for liquid) dynes/cm2 (for bulk modulus) psi (for bulk modulus)
absolute viscosity gram/cm-sec lbf-sec/inch2
density gram/cm3 lbf-sec2/inch4
emissivity (surface property only)    
r wall roughness (surface property only) cm in
D diffusivity cm2/s in2/s