Given: A stainless steel wire is passing a current of 200 A. The wire is 1 m long and 3 mm in diameter. The wire is submerged in a 110°C fluid. the convection coefficient between the fluid and the wire is 0.004 W/(mm 2 °C)
Material Properties:
Thermal conductivity: 0.019 W/(mm°C)
Resistivity: 0.0007 ωmm
Find: The temperature at the center of the wire.
This example only covers setting up and performing the analysis. For instructions on building the model, see Heat Generation Due to Electrical Current Model. If you did not build the model, you can open the heatgen_input.ach file in the Models subfolder of the Autodesk Simulation installation directory.
Design Scenario 1 will be the electrostatic analysis to determine the current flow, and Design Scenario 2 will be the heat transfer analysis to determine the temperature distribution.
Shape
Rectangle and Selection
Select
Vertices to select the nodes along the top edge of the model. Right-click and select Add
Nodal Applied Voltages command. Type 0.198 in the Magnitude field, type 1e8 in the Stiffness field, and click OK. Select the nodes along the bottom edge of the model. Right-click and select Add
Nodal Applied Voltages. Type 0 in the Magnitude field, type 1e8 in the Stiffness field, and click OK.
Analysis
Run Simulation to analyze the model and view the results in the Results environment.
Voltage and Current
Voltage to verify that the voltages vary linearly from 0 to 0.198V.
Voltage and Current
Current
Rate Through Face. Select Results Contours
Settings
Smooth Results to deactivate the smoothing. Use Selection
Select
Faces and Selection
Shape
Rectangle to select the bottom edge of the model. Select Results Inquire
Inquire
Current Results and select the Sum option in the Summary drop-down menu. The results should be close to 200 A.
Environments
FEA Editor to move back to the FEA Editor environment.
Thermal
Steady-State Heat Transfer.Click Yes to create Design Scenario 2, set to heat transfer analysis, with a copy of the complete mesh.
Heat Generation. Type 1 in the Internal Heat Generation field. This will act as a flag to tell the processor to use the heat generation values calculated from the electrostatic analysis for this part. Click OK.
Surface Convection Load.
Analysis
Run Simulation to analyze the model and view the results in the Results environment. An archive of the model heatgen.ach is located in the Models subdirectory of the Autodesk Simulation installation directory. To analyze the model, select the Electrical tab of the Analysis Parameters dialog box and navigate to the proper location of the .efo file.
Reference:
J. P. Holman, Heat Transfer 7th Edition. McGraw Hill. Example 2-4 p. 42.