SetSupplyZone_BI

The feature rule SetSupplyZone_BI sets the supply zone <feature class>.FID_SUPPLYZONE for a feature that is located within a zone. If the feature is located in overlapping zones, you are prompted to select a zone. If you select Yes, you can select a zone. If you select No, the supply zone value is cleared.

Note:

We recommend that you enable the feature rule, if you want to automatically assign the supply zone when you digitize a pipe. See also the Water Module User Guide, section Supply Zones.

Name

SetSupplyZone_BI

Classification

System feature rule. Do not disable.

Location

Assembly: Autodesk.Map.IM.Modules.Water.dll

Classname: Autodesk.Map.IM.Modules.Water.FeatureRules

Type

Client-side

Before Insert (BI).

Is System. Is Row.

Description

Sets the supply zone of a feature if it is within such a zone. When more than one zone is found, the feature is assigned to none.

Parameters

P1: Show Zone Selector. Default is YES.

Specifies whether a zone selector is shown, if more than one zone is found.

Dependency

The SetSupplyZone_BI feature rule applies to the attribute feature classes. There is a related rule group for the utility point and utility line feature classes. See SetSupplyZone_BIU.

Note: