To Activate the Set Supply Zone Feature Rule

When you digitize gas network features, a feature rule sets the supply zone for a line feature if it is located within a zone. If the feature is located in overlapping zones, you are prompted to select a zone. If you select Yes, you can select a zone. If you choose No, the pressure zone value is cleared.

Note:

If you digitize a supply zone while the gas network features already exist, the pipes are not updated and do not belong to the supply zone.

You can use a feature function to update the relations. See also Connect Features to a Zone

To activate the Set Supply Zone feature rule (Line feature class)

  1. In the Maintenance workspace, open the Gas project .
  2. Click Industry Model menu Data Model.
  3. Expand the Utility topic and select the Line feature class (GA_LINE).
  4. Right-click and click Edit Feature Rules.

    The Feature Rules Properties dialog box is displayed.

  5. In the Feature Rules Properties dialog box, click the Client Side (.NET) tab.
  6. In the Applied Rule Bases list, enable the GA_SetSupplyZone_BIU and the GA_SetSupplyZone_AIU rules.
  7. Click Save & Close.

To activate the Set Supply Zone feature rule (Pipe feature class)

  1. In the Maintenance workspace, open the Gas project .
  2. Click Industry Model menu Data Model.
  3. Expand the Pipe topic and select the Pipe feature class (GA_PIPE).
  4. Right-click and click Edit Feature Rules.

    The Feature Rules Properties dialog box is displayed.

  5. In the Feature Rules Properties dialog box, click the Client Side (.NET) tab.
  6. In the Applied Rule Bases list, select the GA_SetSupplyZone_BI rule.
  7. Click Save & Close.