To Set Pressure Zone

When you digitize water network features, a feature rule sets the pressure zone for a feature if it is located within a zone. If the feature is located in overlapping zones, you are prompted to select a zone. If you choose Yes, you can select a zone. If you choose No, the pressure zone value is cleared.

Note:

If you digitize a pressure zone while the water network features already exist, the pipes are not updated and do not belong to the pressure zone.

You can use a feature function to update the relations. See also Connect Features to a Zone.

  1. Start Infrastructure Administrator and open the Water project.
  2. Click Industry Model menu Data Model.
  3. Expand the Utility topic and select the Point feature class.
  4. Right-click and click Edit Feature Rules.

    The Feature Rules Properties dialog box is displayed.

  5. In the Feature Rules Properties dialog box, click the Client Side (.NET) tab.
  6. In the Applied Rule Bases list, enable or disable the SetPressureZone_BIU and the SetPressureZone_AIU rules.
  7. Click Save & Close.
  8. Expand the Point topic and select the Fitting feature class.
  9. Right-click and click Edit Feature Rules.
  10. In the Feature Rules Properties dialog box, click the Client Side (.NET) tab.
  11. In the Applied Rule Bases list, enable or disable the SetPressureZone_BI rule.
  12. Click Save & Close.