When you digitize water network features, a feature rule sets the pressure zone for a feature if it is located within a zone. If the feature is located in overlapping zones, you are prompted to select a zone. If you choose Yes, you can select a zone. If you choose No, the pressure zone value is cleared.
Note:
If you digitize a pressure zone while the water network features already exist, the pipes are not updated and do not belong to the pressure zone.
You can use a feature function to update the relations. See also Connect Features to a Zone.
- Start
Infrastructure Administrator
and open the Water project.
- Click Industry Model menu
Data Model.
- Expand the Utility topic and select the Point feature class.
- Right-click and click Edit Feature Rules.
The Feature Rules Properties dialog box is displayed.
- In the Feature Rules Properties dialog box, click the Client Side (.NET) tab.
- In the Applied Rule Bases list, enable or disable the SetPressureZone_BIU and the SetPressureZone_AIU rules.
- Click Save & Close.
- Expand the Point topic and select the Fitting feature class.
- Right-click and click Edit Feature Rules.
- In the Feature Rules Properties dialog box, click the Client Side (.NET) tab.
- In the Applied Rule Bases list, enable or disable the SetPressureZone_BI rule.
- Click Save & Close.