After clicking , the following dialog displays:
The Parameters of reinforcing bar shape field include the following options:
In the dialog, only the Insert and Points icons are available. When clicked, a definition of a bar is created from the database. The remaining icons are unavailable.
After clicking Shape database…, the Bar database dialog opens.
Structure of the shape database:
To define bars from the database, select a bar from the available shape list, then define the next bar segments by indicating next bar characteristic points presented in a schematic drawing (you may also enter dimensions of individual segments from the keyboard).
Once a bar is selected from the database, the bar segments are defined individually based on the indicated points (there apply rigid rules of defining successive segments so that the bar shape is maintained). While defining, the bar length is calculated automatically. The bar dimensions proposed by default in the dialog are the dimensions of the recently-defined bar.
A bar defined in the bar shape database remembers the shape of a selected bar type. You can replace the bar with a regular bar which does not remember the bar geometrical shape - to do that, use the EXPLODE option.
There is also another method for defining bars. Once the Shape parameters… button is clicked, the additional dialog displays, and a table containing dimensions of individual bar segments is available. After determining bar dimensions, a completed bar may be added to a formwork.
The above dialog contains a table that displays dimensions of bar segments.
The field with a shape code is filled out automatically depending on a typical shape selected.
Both modes of reinforcement definition are synchronized with each other; both definition modes can be used alternately.
See also:
Commands from the command line - definition of transversal reinforcement