Components Element Reference

The Components element is used to specify the components that make up one version of the plug-in.

More than one Components element can be used to identify the components for a plug-in; each Components element can identify one or more components. Platform and product information for a Components element is defined with the RuntimeRequirements element.

If all the components defined within a Components element apply to the same platform, you do not need to add a RuntimeRequirements element to each individual ComponentEntry element.

Along with the RuntimeRequirements element, the Components element can contain one or more of the following elements

Note: A Components element can only have one RegistryEntries, SystemVariables, and EnvironmentVariables elements but can contain multiple ComponentEntry elements.

The following outlines the basic relationship of the Components element and any elements it can contain.

<Components>
  <RuntimeRequirements ... />

  <RegistryEntries>
    <RegistryEntry ... />
  </RegistryEntries>

  <SystemVariables>
    <SystemVariable ... />
  </SystemVariables>

  <EnvironmentVariables>
    <EnvironmentVariable ... />
  </EnvironmentVariables>

  <ComponentEntry ... >
    <RuntimeRequirements ... />
  </ComponentEntry>

  <ComponentEntry ... />

  <Commands ...>
    <Command ... />
  </Commands>
</Components>

ComponentEntry Element - Supported in AutoCAD 2013-based products and later

The ComponentEntry element is required and is used to specify details about each individual component in the Components element.

You can specify as many ComponentEntry elements as needed. Component types can be one of the following file formats:

A ComponentEntry element may contain a Commands element if the LoadReasons attribute is set to LoadOnCommandInvocation.

Note: ComponentEntry elements are loaded in the order they are listed, but from the bottom up. Therefore, any files that other components are dependent on must be lower down the list. For example, if an ObjectARX module is dependent on an ObjectDBX module, then the ObjectARX module will need to appear above the ObjectDBX module in the list.

A ComponentEntry element can have any of the following attributes attached to it:

Attribute

Description

AppName

Optional for AutoLISP; Required for ObjectARX and .NET - Component name; same as AppName in the ObjectARX API AcadAppInfo class.

AppDescription

Component description; same as AppDescription in the ObjectARX API AcadAppInfo class.

AppType

Component type; overrides the type derived from the file extension provided in the ModuleName attribute.

The component type can be one of the following:

  • .Net – Managed or Mixed .NET assembly
  • Arx – ObjectARX
    Note: Required to load an ARX file from a bundle into AutoCAD for Mac.
  • Atc – Tool palette
  • Bundle - Bundle package
  • Cui or CuiX – Partial customization
  • Dbx – ObjectDBX
  • Dependency – Resource DLL (not to be loaded into the AutoCAD-based product)
  • JavaScript – JavaScript
  • Lisp or CompiledLisp – AutoLISP/Visual LISP
  • Mnu – Menu customization
  • VBA – VBA Project
  • Xaml – XAML file used to implement a contextual ribbon tab

ModuleName

Relative path to the component within the bundle; same as ModuleName in the ObjectARX API AcadAppInfo class.

The component type is determined from the file extension:

  • .atc – Tool palette
  • .arx – ObjectARX
  • .cuix – Partial customization
  • .dbx – ObjectDBX
  • .dll – Managed .NET assembly
  • .dvb – VBA Project (AutoCAD 2015)
    Note: DVB files require the VBA Enabler to be installed first. When loaded, the user needs to click "Enable Macros" before the project and its macros can be accessed.
  • .js – Javascript (AutoCAD 2015)
  • .lsp, .fas, or .vlx – AutoLISP/Visual LISP
  • .xaml – Extensible Application Markup Language (AutoCAD 2015)
    Note: Attribute XamlType must be set to "ContextualTabRule"

If your application will handle multiple languages, different versions of a specific component can be specified by combining ModuleName with a locale code. See Supported Locale Codes Reference for a full list of supported locale codes.

Note: All path specifiers are '/' and not '\', and paths are relative to the root .bundle folder.

PerDocument

AutoLISP only - When True, the AutoLISP file is loaded once per document. Default is True.

Loadreasons

Multiple values can be specified - Defines the load behavior parameters for the component with LoadReasons and the exception of the LoadOnCommandInvocation parameter.

By default, LoadOnAutoCADStartup, LoadOnAppearance, and LoadOnProxy are enabled (set to True) if LoadReasons is not specified. If parameters need to be disabled (set to False), the LoadReasons element must be specified along with the parameters set to False.

By default, LoadOnCommandInvocation is disabled, enabling it will disable LoadOnAutoCADStartup and LoadOnAppearance unless they are explicitly enabled.

See the ObjectARX Reference Guide for full details on AcadAppInfo LoadReasons.

Valid parameter values:

  • True – Parameter is enabled
  • False – Parameter is disabled

The following parameters are available:

  • LoadOnCommandInvocation. Load only when a custom commands is invoked. When using this parameter, a ‘Commands’ element must be included. If LoadOnCommandInvocation is enabled, LoadOnAutoCADStartup and LoadOnAppearance are assumed to be disabled unless explicitly enabled. Only applies to AutoLISP, ObjectARX, and .NET modules.
    Note: For startup performance reasons, it is very important to use this option when your components define commands.
  • LoadOnAutoCADStartup. Load when the AutoCAD-based product starts up. When specified, this parameter has precedence over all other parameters. It is recommended only to use LoadOnAutoCADStartup when none of the other parameters are suitable, disable it (set it to False) whenever possible. If the LoadOnAutoCADStartup parameter is omitted, then it defaults to enabled (set to True) unless LoadOnCommandInvocation is enabled, in which case LoadOnAutoCADStartup defaults to False. Only applies to ObjectARX and .NET modules.
  • LoadOnProxy. Load when a proxy for a custom entity is detected. By default, this parameter is enabled unless explicitly disabled (set to False). When enabled (set to True), LoadOnAutoCADStartup should be disabled. Only applies to ObjectDBX files.
  • LoadOnAppearance. Load when the product detects the application bundle in one of the ApplicationPlugins folders, thereby supporting instant load on installation with no need to restart the AutoCAD-based product. The parameter behaves the same way as LoadOnAutoCADStartup except the load context is relevant to when an application is installed while the product is running, for instance if installed via the Autodesk Exchange Apps website.

XamlType

XAML type; currently the only supported value is "ContextualTabRule" and it is required when a XAML file is assigned to the ModuleName attribute. The application file that uses the XAML file should be listed after the ComponentEntry element that contains the XAML file.

RegistryEntries Element - Supported in AutoCAD 2015-based products

The RegistryEntries element is optional, and can contain one or more RegistryEntry elements. A RegistryEntry element contains the definition of a registry entry that the plug-in should create or modify. Registry entries are stored in the Windows Registry or in a property list (PLIST) file on Mac OS.

Note: On Windows, registry entries are created under HKEY_CURRENT_USER\Software\Autodesk\AutoCAD\<release>\ACAD-<product>:<language>. It is not possible to create registry entries in other locations. The equivalent location is used in the PLIST files on Mac OS.
RegistryEntry Element

Attribute

Description

Name

Name of the registry entry to create or modify.

Value

Value to assign to the registry entry.

The value can include one of the optional operator prefixes: +, -, &, and |.

See the "Variable Value Operator Prefixes" section for more information.

Note: The operator prefix is not retained when the value is applied to the registry entry.

Type

Data type to assign to the registry entry. Optional when modifying an existing registry entry.

Valid values are:

  • REG_SZ – String; null terminated
  • REG_EXPAND_SZ – String containing an unexpanded environment variable, such as %APPDATA%; null terminated
  • REG_DWORD – 32-bit unsigned integer
  • REG_QWORD – 64-bit signed integer

If an operator prefix is used as part of the registry entry's value, the appropriate data type must be specified. If the appropriate data type is not used, the operation will be treated as a string operation.

Flags

Optional, creation and modification flags. Multiple flags can be specified; use a pipe symbol to separate each flag.

The following flags are supported:

  • Create – Registry entry is created if it does not exist. (Default behavior)
  • Open – Modifies the value of the registry entry each time the plug-in is loaded, and only when the registry entry exists.
  • OpenOnce – Modifies the value of the registry entry upon the very first time the plug-in is loaded, and only when the registry entry exists. Uninstalling and reinstalling the plug-in causes the value of the registry entry to be changed again.
Note: The Open or OpenOnce flag must be used to modify the value of a registry entry.

The following example creates the registry key MYREGKEY and adds the values STRING and NUMBER:

<RegistryEntries>
    <RegistryEntry
        Key="MYREGKEY"
        Name="STRING"
        Value="Example"
        Type="REG_SZ"
    />

    <RegistryEntry
        Key="MYREGKEY"
        Name="NUMBER"
        Value="123"
        Type="REG_DWORD"
    />
</RegistryEntries>

SystemVariables Element - Supported in AutoCAD 2015-based products

The SystemVariables element is optional, and can contain one or more SystemVariables elements. A SystemVariable element contains the definition of a system variable that the plug-in should create or modify.

SystemVariable Element

Attribute

Description

Name

Name of the system variable to create or modify.

Value

Value to assign to the variable.

The value can include one of the optional operator prefixes: +, -, &, and |.

See the "Variable Value Operator Prefixes" section for more information.

Note: The operator prefix is not retained when the value is applied to the variable.

PrimaryType

Data type to assign to the variable. Optional when modifying an existing system variable.

Valid values are:

  • Int16 – 16-bit signed integer
  • Int32 – 32-bit integer
  • Real – Float or double numeric value
  • String – Single or multiple character value

If an operator prefix is used as part of the variable's value, the appropriate data type must be specified. If the appropriate data type is not used, the operation will be treated as a string operation.

StorageType

Storage location for the variable's value; when persisted. Optional when modifying an existing system variable.

Valid values are:

  • Database – Persisted in the drawing file the variable is created
  • Profile – Persisted as part of the current AutoCAD profile
  • Session – Not retained between sessions or in the drawing it is created
  • User – Persisted as part of the FixedProfile for AutoCAD

Owner

Optional, AcRX service name.

Used to make a system variable read-only and only modifiable by the application that registers the service name using acrxRegisterService().

Flags

Optional, creation and modification flags. Multiple flags can be specified; use a pipe symbol to separate each flag.

The following flags are supported:

  • Create – Variable is created if it does not exist. (Default behavior)

  • Open – Modifies the value of the variable each time the plug-in is loaded, and only when the variable exists.

  • OpenOnce – Modifies the value of the variable upon the very first time the plug-in is loaded, and only when the variable exists. Uninstalling and reinstalling the plug-in causes the value of the variable to be changed again.

  • SpacesAllowed – Allows for the pressing of the Spacebar at the Command prompt. If not specified, pressing the Spacebar is the same as pressing Enter.

    Note: Use only with the Create flag and when the PrimaryType attribute is set to String.
  • DotIsEmpty – Allows for the clearing of a variable's value by entering a "." (period) for the value of the variable.

    Note: Use only with the Create flag and when the PrimaryType attribute is set to String.
  • NoUndo – Changes to the variable are not recorded and cannot be undone with the U or UNDO commands.

    Note: Use only with the Create flag.
  • Chatty – Triggers a reactor notification even when the value of the variable is set to its current value.

    Note: Use only with the Create flag.
Note: The Open or OpenOnce flag must be used to modify the value of a variable.

The following example creates a system variable named MYVARIABLE:

<SystemVariable
    Name="MYVARIABLE"
    PrimaryType="String"
    StorageType="User"
    Value="Example"
    Owner=""
    Flags="Create|DotIsEmpty|SpacesAllowed"
/>

The following example changes the value of the CURSORSIZE system variable to 100 when the plug-in is loaded the first time:

<SystemVariable
    Name="CURSORSIZE"
    Value="100"
    Flags="OpenOnce"
/>

EnvironmentVariables Element - Supported in AutoCAD 2015-based products

The EnvironmentVariables element is optional, and can contain one or more EnvironmentVariable elements. A EnvironmentVariable element contains the definition of an environment variable that the plug-in should create or modify. Environment variables are stored in the Windows Registry or in a property list (PLIST) file on Mac OS.

Note: The value of an environment variable is always stored as a string, and the name of an environment variable is case sensitive.
EnvironmentVariable Element

Attribute

Description

Name

Name of the environment variable to create or modify.

Value

Value to assign to the variable.

The value can include one of the optional operator prefixes: +, -, &, and |.

See the "Variable Value Operator Prefixes" section for more information.

Note: The operator prefix is not retained when the value is applied to the variable.

Type

Optional, data type that Value represents.

Valid values are:

  • Int16 – 16-bit signed integer
  • Int32 – 32-bit signed integer
  • Real – Float or double numeric value
  • String – Single or multiple character value

If an operator prefix is used as part of the variable's value, the appropriate data type must be specified. If the appropriate data type is not used, the operation will be treated as a string operation.

Flags

Optional, creation and modification flags. Multiple flags can be specified; use a pipe symbol to separate each flag.

The following flags are supported:

  • Create – Variable is created if it does not exist. (Default behavior)
  • Open – Modifies the value of the variable each time the plug-in is loaded, and only when the variable exists.
  • OpenOnce – Modifies the value of the variable upon the very first time the plug-in is loaded, and only when the variable exists. Uninstalling and reinstalling the plug-in causes the value of the variable to be changed again.
Note: The Open or OpenOnce flag must be used to modify the value of a variable.

The following is an example of creating two environment variables named MYNUMVAR and MYSTRVAR:

<EnvironmentVariables>
    <EnvironmentVariable
        Name="MYNUMVAR"
        Value="123"
    />

    <EnvironmentVariable
        Name="MYSTRVAR"
        Value="Example"
    />
</EnvironmentVariables>

Operator Prefixes for Variable Values

Operator prefixes are used to modify the current value of a variable when the plug-in is loaded. You can add one of the operator prefixes listed in the following table to the Value attribute of a RegistryEntry, SystemVariable, or EnvironmentVariable element.

Prefix

Description

+ (plus sign)

Adds or appends a value to an existing variable's value.

Int16, Int32, Real: Adds Value to an existing variable's value.

String: Appends Value to an existing variable's value.

- (hyphen)

Subtracts or removes a value to an existing variable's value.

Int16, Int32, Real: Subtracts Value from an existing variable's value.

String: Removes Value from an existing variable's value.

& (ampersand)

Bitwise-and operation with the existing value of the variable; only numeric values are supported.

| (pipe symbol)

Bitwise-or operation with the existing value of the variable; only numeric values are supported.

Note: If the value of a variable is supposed to start with one of the operator prefixes, add a backslash before the operator. For example, if the variable's value is supposed to be +radius, enter the value as \+radius.

The following always enables the END, MID, CEN, NOD, QUA, and INT running object snaps, and leaves all other object snap settings as-is:

<SystemVariable
    Name="OSMODE"
    Value="|63"
    Flags="Open"
/>

Commands Element - Supported in AutoCAD 2013-based products and later

The Commands element is optional unless the LoadOnCommandInvocation parameter is enabled for the LoadReasons attribute. Used to specify which commands to register for LoadOnCommandInvocation.

You can specify more than one Command element as needed.

A Commands element can have the following attribute attached to it:

Attribute

Description

GroupName

Name used to organize related commands.

Command Element - Supported in AutoCAD 2013-based products and later

Specifies the global and local names for each command.

A Command element can have any of the following attributes attached to it:

Attribute

Description

Global

Global command name.

Local

Local command name.

Commands can be defined for multiple languages by combining Local with a locale code. See Supported Locale Codes Reference for a full list of supported locale codes.

HelpTopic

Help topic to open when the command is active and F1 is pressed.

Note: To display the help topic, a help file must be assigned to the plug-in. The help file location for the plug-in is specified with the HelpFile attribute under the ApplicationPackage element.

StartupCommand

Executes the command at startup when True.