Changes what data fields are reported and the order in which they appear.
FindSelect Terminal Plan from the report list. Run the report and click Change Report Format on the Report Generator dialog box.
Available Fields |
Lists the available fields for formatting the report (including user-defined attributes). Select a field from the list to transfer it into the Fields to Report list. |
Fields to Report |
Lists the fields to display in the report. |
Remove/Remove All |
Removes the selected field or all fields from the Fields to Report list. |
Move Up |
Moves the selected field up one spot in the Fields to Report list. |
Move Down |
Moves the selected field down one spot in the Fields to Report list. |
Change field name/justification |
Specifies the vertical and horizontal justification (Top Left, Middle Center, Bottom Right) of any column and the column label (default is Top Left). The vertical portion of the justification (Top, Middle, Bottom) is only used for the Put on Drawing report feature. For example, if you select "Top Right" the report is right-justified during the display, printing and when saved to a file (the "top" portion is ignored). If you put the report on the drawing, the report justification is top right. |
INST1 |
"From" device's installation code |
LOC1 |
"From" device's location code (must end with "1") |
CMP1 |
"From" device's component tag ID (must end with "1") |
PIN1 |
"From" device's wire connection terminal number (must end with "1") |
PD1 |
"From" device's wire connection TERMDESC value (must end with "1") |
LAYCMP1 |
Layer of wire connecting to device component 1 (must end with "1") |
CBL1 |
Cable ID tied to device component 1 (must end with "1") |
CBLWC1 |
Cable wire color tied to device component 1 (must end with "1") |
WNUM1 |
Wire number tied to device component 1 (must end with "1") |
LAYTRM1 |
Layer of wire connecting to terminal side 1 (must end with "1") |
STRIP-ID |
Terminal strip TAGSTRIP ID name |
TD1 |
Terminal pin TERMDESC value for the first wire connection (must end with "1") |
TERM |
Terminal or terminal number assignment (not the STRIP-ID value) |
TD2 |
Terminal pin TERMDESC value for the second wire connection (must end with "2") |
TINST |
Terminal symbol's installation value |
TLOC |
Terminal symbol's location value |
LAYTRM2 |
Layer of wire connecting to terminal side 2 (must end with "2") |
WNUM2 |
Wire number tied to device component 2 (must end with "2") |
CBL2 |
Cable ID tied to device component 2 (must end with "2") |
CBLWC2 |
Cable wire color tied to device component 2 (must end with "2") |
LAYCMP2 |
Layer of wire connecting to device component 2 (must end with "2") |
PD2 |
"To" device's wire connection TERMDESC value (must end with "2") |
PIN2 |
"To" device's wire connection terminal number (must end with "2") |
CMP2 |
"To" device's component tag ID (must end with "2") |
INST2 |
"To" device's installation code |
LOC2 |
"To" device's location code (must end with "2") |
SH |
Sheet - the %S value |
REF |
Line reference or X-Y grid reference or X-Zone reference |
HDL |
Entity handle number |
XDIR1 |
"From" device's wire connection point direction - i.e. 4 = connects from left (must end with "1") |
XDIR2 |
"To" device's wire connection point direction - i.e. 2 = connects from above (must end with "2") |
DWGIX |
"From" device's drawing DWGIX value as listed in FILETIME table of project scratch database |