Terminal Plan Data Fields to Report Dialog Box

Changes what data fields are reported and the order in which they appear.

Find
 Command entry:  AESCHEMATICREPORT

Select Terminal Plan from the report list. Run the report and click Change Report Format on the Report Generator dialog box.

Available Fields

Lists the available fields for formatting the report (including user-defined attributes). Select a field from the list to transfer it into the Fields to Report list.

Fields to Report

Lists the fields to display in the report.

Remove/Remove All

Removes the selected field or all fields from the Fields to Report list.

Move Up

Moves the selected field up one spot in the Fields to Report list.

Move Down

Moves the selected field down one spot in the Fields to Report list.

Change field name/justification

Specifies the vertical and horizontal justification (Top Left, Middle Center, Bottom Right) of any column and the column label (default is Top Left). The vertical portion of the justification (Top, Middle, Bottom) is only used for the Put on Drawing report feature. For example, if you select "Top Right" the report is right-justified during the display, printing and when saved to a file (the "top" portion is ignored). If you put the report on the drawing, the report justification is top right.

Available Fields

INST1

"From" device's installation code

LOC1

"From" device's location code (must end with "1")

CMP1

"From" device's component tag ID (must end with "1")

PIN1

"From" device's wire connection terminal number (must end with "1")

PD1

"From" device's wire connection TERMDESC value (must end with "1")

LAYCMP1

Layer of wire connecting to device component 1 (must end with "1")

CBL1

Cable ID tied to device component 1 (must end with "1")

CBLWC1

Cable wire color tied to device component 1 (must end with "1")

WNUM1

Wire number tied to device component 1 (must end with "1")

LAYTRM1

Layer of wire connecting to terminal side 1 (must end with "1")

STRIP-ID

Terminal strip TAGSTRIP ID name

TD1

Terminal pin TERMDESC value for the first wire connection (must end with "1")

TERM

Terminal or terminal number assignment (not the STRIP-ID value)

TD2

Terminal pin TERMDESC value for the second wire connection (must end with "2")

TINST

Terminal symbol's installation value

TLOC

Terminal symbol's location value

LAYTRM2

Layer of wire connecting to terminal side 2 (must end with "2")

WNUM2

Wire number tied to device component 2 (must end with "2")

CBL2

Cable ID tied to device component 2 (must end with "2")

CBLWC2

Cable wire color tied to device component 2 (must end with "2")

LAYCMP2

Layer of wire connecting to device component 2 (must end with "2")

PD2

"To" device's wire connection TERMDESC value (must end with "2")

PIN2

"To" device's wire connection terminal number (must end with "2")

CMP2

"To" device's component tag ID (must end with "2")

INST2

"To" device's installation code

LOC2

"To" device's location code (must end with "2")

SH

Sheet - the %S value

REF

Line reference or X-Y grid reference or X-Zone reference

HDL

Entity handle number

XDIR1

"From" device's wire connection point direction - i.e. 4 = connects from left (must end with "1")

XDIR2

"To" device's wire connection point direction - i.e. 2 = connects from above (must end with "2")

DWGIX

"From" device's drawing DWGIX value as listed in FILETIME table of project scratch database