Changes what data fields are reported and the order in which they appear.
FindSelect PLC I/O Address and Descriptions from the report list. Run the report and click Change Report Format on the Report Generator dialog box.
Available Fields |
Lists the available fields for formatting the report (including user-defined attributes). Select a field from the list to transfer it into the Fields to Report list. |
Fields to Report |
Lists the fields to display in the report. |
Remove/Remove All |
Removes the selected field or all fields from the Fields to Report list. |
Move Up |
Moves the selected field up one spot in the Fields to Report list. |
Move Down |
Moves the selected field down one spot in the Fields to Report list. |
Change field name/justification |
Specifies the vertical and horizontal justification (Top Left, Middle Center, Bottom Right) of any column and the column label (default is Top Left). The vertical portion of the justification (Top, Middle, Bottom) is only used for the Put on Drawing report feature. For example, if you select "Top Right" the report is right-justified during the display, printing and when saved to a file (the "top" portion is ignored). If you put the report on the drawing, the report justification is top right. |
TAGNAME |
Tag ID value (attributes "TAG", "TAG1", "TAGSTRIP", "P_TAG1") |
ADDR |
PLC I/O point's address assignment |
TERM |
Terminal or terminal number assignment (not the STRIP-ID value) |
TERMDESC |
Component wire connection TERMDESCxx value |
DESCA-DESCE |
PLC I/O point description attribute values (lines 1-5) |
LREF |
Line reference |
WIRENO |
Wire number |
INST |
Installation attribute value |
LOC |
Location attribute value |
MFG |
Manufacturer or vendor name (for example, Siemens) |
CAT |
Catalog part number assignment |
ASSYCODE |
Optional assembly code value used in catalog lookup query to get part number groups |
LINE1 |
PLC I/O LINE1 attribute description text |
LINE2 |
PLC I/O LINE2 attribute description text |
HDL |
Entity handle number |
XTERMHDL |
Wire connection X?TERMxx attribute's entity handle name |
TERMCODE |
Wire connection X?TERMxx attribute suffix (the "xx") |
SH |
Sheet - the %S value |
SHDWGNAM |
Drawing name - the %D value |
IEC_P |
Drawing's IEC project default - the %P value |
IEC_I |
Drawing's IEC Installation default - the %I value |
IEC_L |
Drawing's IEC Location default - the %L value |
SEC |
Drawing section assignment |
SUBSEC |
Drawing sub-section assignment |
DWGIX |
"From" device's drawing DWGIX value as listed in FILETIME table of project scratch database |