PLC I/O Address and Descriptions Data Fields to Report Dialog Box

Changes what data fields are reported and the order in which they appear.

Find
 Command entry:  AESCHEMATICREPORT

Select PLC I/O Address and Descriptions from the report list. Run the report and click Change Report Format on the Report Generator dialog box.

Available Fields

Lists the available fields for formatting the report (including user-defined attributes). Select a field from the list to transfer it into the Fields to Report list.

Fields to Report

Lists the fields to display in the report.

Remove/Remove All

Removes the selected field or all fields from the Fields to Report list.

Move Up

Moves the selected field up one spot in the Fields to Report list.

Move Down

Moves the selected field down one spot in the Fields to Report list.

Change field name/justification

Specifies the vertical and horizontal justification (Top Left, Middle Center, Bottom Right) of any column and the column label (default is Top Left). The vertical portion of the justification (Top, Middle, Bottom) is only used for the Put on Drawing report feature. For example, if you select "Top Right" the report is right-justified during the display, printing and when saved to a file (the "top" portion is ignored). If you put the report on the drawing, the report justification is top right.

Available Fields

TAGNAME

Tag ID value (attributes "TAG", "TAG1", "TAGSTRIP", "P_TAG1")

ADDR

PLC I/O point's address assignment

TERM

Terminal or terminal number assignment (not the STRIP-ID value)

TERMDESC

Component wire connection TERMDESCxx value

DESCA-DESCE

PLC I/O point description attribute values (lines 1-5)

LREF

Line reference

WIRENO

Wire number

INST

Installation attribute value

LOC

Location attribute value

MFG

Manufacturer or vendor name (for example, Siemens)

CAT

Catalog part number assignment

ASSYCODE

Optional assembly code value used in catalog lookup query to get part number groups

LINE1

PLC I/O LINE1 attribute description text

LINE2

PLC I/O LINE2 attribute description text

HDL

Entity handle number

XTERMHDL

Wire connection X?TERMxx attribute's entity handle name

TERMCODE

Wire connection X?TERMxx attribute suffix (the "xx")

SH

Sheet - the %S value

SHDWGNAM

Drawing name - the %D value

IEC_P

Drawing's IEC project default - the %P value

IEC_I

Drawing's IEC Installation default - the %I value

IEC_L

Drawing's IEC Location default - the %L value

SEC

Drawing section assignment

SUBSEC

Drawing sub-section assignment

DWGIX

"From" device's drawing DWGIX value as listed in FILETIME table of project scratch database