Changes what data fields are reported and the order in which they appear.
FindSelect Wire Label from the report list. Run the report and click Wire Label on the Report Generator dialog box.
Available Fields |
Lists the available fields for formatting the report (including user-defined attributes). Select a field from the list to transfer it into the Fields to Report list. |
Fields to Report |
Lists the fields to display in the report. |
Remove/Remove All |
Removes the selected field or all fields from the Fields to Report list. |
Move Up |
Moves the selected field up one spot in the Fields to Report list. |
Move Down |
Moves the selected field down one spot in the Fields to Report list. |
Separator |
Specifies the special character to separate the selected fields. Enter a special character to separate the selected fields inside the list box. Do this by selecting a field from the Fields to Report list, define the separator, select another field, define a separator, and so on. You can also select the separator from a list. The "\n" symbol stands for the new line. When you use this as separator, the field displays in the new (next) line. |
WIRENO |
Wire number |
CMP |
Component that connects to a wire (at any end) and is written to the wire label |
PIN |
Wire connection terminal pin number of the component that the wire connects with |