Changes what data fields are reported and the order in which they appear.
FindSelect Wire Annotation Exception from the report list. Run the report and click Change Report Format on the Report Generator dialog box.
Available Fields |
Lists the available fields for formatting the report (including user-defined attributes). Select a field from the list to transfer it into the Fields to Report list. |
Fields to Report |
Lists the fields to display in the report. |
Remove/Remove All |
Removes the selected field or all fields from the Fields to Report list. |
Move Up |
Moves the selected field up one spot in the Fields to Report list. |
Move Down |
Moves the selected field down one spot in the Fields to Report list. |
Change field name/justification |
Specifies the vertical and horizontal justification (Top Left, Middle Center, Bottom Right) of any column and the column label (default is Top Left). The vertical portion of the justification (Top, Middle, Bottom) is only used for the Put on Drawing report feature. For example, if you select "Top Right" the report is right-justified during the display, printing and when saved to a file (the "top" portion is ignored). If you put the report on the drawing, the report justification is top right. |
TAGNAME |
Tag ID value (attributes "TAG", "TAG1", "TAGSTRIP", "P_TAG1") |
PIN |
Wire connection terminal pin number |
WIRENO |
Wire number |
WTYPE |
Alternate type of symbol (for example, "PN" for pneumatic, "HY" for hydraulic) |
INST |
Installation attribute value |
LOC |
Location attribute value |
MOUNT |
Mount attribute value; panel layout optional attribute for user-defined "panel mounting" assignment |
GROUP |
GROUPWITH attribute value; panel layout optional attribute for user-defined "group with" assignment |
END1 |
Component and connection information on one end of wire (must end with "1") |
END2 |
Component and connection information on one end of wire (must end with "2") |
BLKNAME |
WDBLKNAM attribute value used for the linking of symbols to tables in the Default CAT database |
DWGIX |
"From" device's drawing DWGIX value as listed in FILETIME table of project scratch database |
HDL |
Entity handle number |
CATEGORY |
Type of component (J = plug-jack connector, P = PLC I/O, C = cable marker, FP = Panel Footprint, FPT = terminal footprint) |
PDESC |
Wire connection point description attribute value |
SFX |
Values of R or L; used for terminal block symbols where we identify the wire annotation attributes with an R or L for Right or Left of the symbol |
SH |
Sheet - the %S value |
SHDWGNAM |
Drawing name - the %D value |
CBL |
Cable tag |
TEXT |
Wire annotation text |