Changes what data fields are reported and the order in which they appear.
FindSelect PLC I/O Component Connection from the report list. Run the report and click Change Report Format on the Report Generator dialog box.
Available Fields |
Lists the available fields for formatting the report (including user-defined attributes). Select a field from the list to transfer it into the Fields to Report list. |
Fields to Report |
Lists the fields to display in the report. |
Remove/Remove All |
Removes the selected field or all fields from the Fields to Report list. |
Move Up |
Moves the selected field up one spot in the Fields to Report list. |
Move Down |
Moves the selected field down one spot in the Fields to Report list. |
Change field name/justification |
Specifies the vertical and horizontal justification (Top Left, Middle Center, Bottom Right) of any column and the column label (default is Top Left). The vertical portion of the justification (Top, Middle, Bottom) is only used for the Put on Drawing report feature. For example, if you select "Top Right" the report is right-justified during the display, printing and when saved to a file (the "top" portion is ignored). If you put the report on the drawing, the report justification is top right. |
PLCWNUM |
Wire number associated with PLC I/O point |
PLCTAG |
PLC tag ID value (attribute "TAG" or "TAG1") |
PLCADDR |
PLC I/O point address (attribute "TAGAxx" where xx is "01" - "xx") |
PLCDESCA-PLCDESCE |
PLC I/O description text lines 1 - 5 |
PLCTERM |
PLC I/O terminal text value, attribute TERMxx |
PLCTERMDESC |
PLC I/O terminal description text value, attribute TERMDESCxx |
PLCINST |
PLC I/O module's Installation attribute value |
PLCLOC |
PLC I/O module's Location attribute value |
WLAY |
Wire layer name |
PLCMFG |
PLC I/O module's Manufacturer attribute value |
PLCCAT |
PLC I/O module's Catalog part number |
PLCASSYCODE |
PLC I/O module's ASSYCODE attribute value |
PLCTERMCODE |
PLC I/O terminal attribute suffix value (the "xx" part of TERMxx) |
PLCDWGIX |
PLC Drawing DWGIX value as listed in FILETIME table of project |
PLCHDL |
PLC I/O module's AutoCAD handle value |
PLCLINE1 |
PLC I/O module's LINE1 attribute value (miscellaneous text such as "Rack" or "Slot") |
PLCLINE2 |
PLC I/O module's LINE2 attribute value (miscellaneous text such as "Rack" or "Slot") |
CMPTAG |
Connected component tag ID (attributes "TAG1", "TAG2", "TAGSTRIP") |
CMPDESC1-3 |
Connected component description attribute values 1 - 3 |
CMPINST |
Connected component Installation attribute value |
CMPLOC |
Connected component Location attribute value |
CMPTERM |
Connected component TERMxx attribute value (the side that connects to the PLC I/O point) |
CMPTERMDESC |
Connected component TERMDESCxx attribute value (the side that connects to the PLC I/O point) |
CMPMFG |
Connected component Manufacturer attribute value |
CMPCAT |
Connected component catalog part number |
CMPASSYCODE |
Connected component ASSYCODE attribute value |
CMPDWGIX |
Connected component's Drawing DWGIX value as listed in FILETIME table of project scratch database |
CMPHDL |
Connected component's AutoCAD handle value |
CMPBLKNAM |
Connected component's AutoCAD block name |
TERMTAG |
Connected terminal's TAGSTRIP attribute value |
TERMINST |
Connected terminal's Installation attribute value |
TERMLOC |
Connected terminal's Location attribute value |
TERMTERM |
Connected terminal's TERM or TERM01 attribute value |
TERMTERMDESC |
Connected terminal's TERMDESC01 attribute value |
TERMMFG |
Connected terminal's Manufacturer attribute value |
TERMCAT |
Connected terminal's catalog part number |
TERMASSYCODE |
Connected terminal's ASSYCODE attribute value |
TERMDWGIX |
Connected terminal's Drawing DWGIX value as listed in FILETIME table of project scratch database |
TERMHDL |
Connected terminal's AutoCAD handle value |
TERMBLKNAM |
Connected terminal's AutoCAD block name |
CBL |
Cable tag |
CBLWC |
Cable wire or cable core color |
CBLHDL |
Cable entity's handle value |