Panel Missing Level/Sequence Assignments Data Fields to Report Dialog Box

Changes what data fields are reported and the order in which they appear.

Find
 Command entry:  AEPANELREPORT

Select Missing Level/Sequence Assignments from the report list. Run the report and click Change Report Format on the Report Generator dialog box.

Available Fields

Lists the available fields for formatting the report (including user-defined attributes). Select a field from the list to transfer it into the Fields to Report list.

Fields to Report

Lists the fields to display in the report.

Remove/Remove All

Removes the selected field or all fields from the Fields to Report list.

Move Up

Moves the selected field up one spot in the Fields to Report list.

Move Down

Moves the selected field down one spot in the Fields to Report list.

Change field name/justification

Specifies the vertical and horizontal justification (Top Left, Middle Center, Bottom Right) of any column and the column label (default is Top Left). The vertical portion of the justification (Top, Middle, Bottom) is only used for the Put on Drawing report feature. For example, if you select "Top Right" the report is right-justified during the display, printing and when saved to a file (the "top" portion is ignored). If you put the report on the drawing, the report justification is top right.

Available Fields

TAGNAME

Tag ID value (attributes "TAG", "TAG1", "TAGSTRIP", "P_TAG1")

INST

Installation attribute value

LOC

Location attribute value

MOUNT

Mount attribute value; panel layout optional attribute for user-defined "panel mounting" assignment

GROUP

GROUPWITH attribute value; panel layout optional attribute for user-defined "group with" assignment

HDL

Entity handle number

CATEGORY

Type of component (J = plug-jack connector, P = PLC I/O, C = cable marker)

DESC1-3

Description attribute values 1-3

SH

Sheet - the %S value

SHDWGNAM

Drawing name - the %D value

FILENAME