Changes what data fields are reported and the order in which they appear.
Find
Command entry:
AESCHEMATICREPORT
Select Wire Label from the report list. Run the report and click Cable Label on the Report Generator dialog box.
|
Available Fields |
Lists the available fields for formatting the report (including user-defined attributes). Select a field from the list to transfer it into the Fields to Report list. |
|
Fields to Report |
Lists the fields to display in the report. |
|
Remove/Remove All |
Removes the selected field or all fields from the Fields to Report list. |
|
Move Up |
Moves the selected field up one spot in the Fields to Report list. |
|
Move Down |
Moves the selected field down one spot in the Fields to Report list. |
|
Separator |
Specifies the special character to separate the selected fields. Enter a special character to separate the selected fields inside the list box. Do this by selecting a field from the Fields to Report list, define the separator, select another field, define a separator, and so on. You can also select the separator from a list. The "\n" symbol stands for the new line. When you use this as separator, the field displays in the new (next) line. |
|
CBL |
Cable name |
|
LOC1 |
Location of "From" components |
|
FROM_CMPS |
Components that are in the "From" end of cable |
|
LOC2 |
Location of "To" components |
|
TO_CMPS |
Components that are in the "To" end of cable |
|
DESC1CBL-DESC3CBL |
Cable's description lines 1-3 |