Cable From/To Data Fields to Report

Changes what data fields are reported and the order in which they appear.

Find
 Command entry:  AESCHEMATICREPORT

Select Cable From/To from the report list. Run the report. Select the location codes for the report and click Change Report Format on the Report Generator dialog box.

Available Fields

Lists the available fields for formatting the report (including user-defined attributes). Select a field from the list to transfer it into the Fields to Report list.

Fields to Report

Lists the fields to display in the report.

Remove/Remove All

Removes the selected field or all fields from the Fields to Report list.

Move Up

Moves the selected field up one spot in the Fields to Report list.

Move Down

Moves the selected field down one spot in the Fields to Report list.

Change field name/justification

Specifies the vertical and horizontal justification (Top Left, Middle Center, Bottom Right) of any column and the column label (default is Top Left). The vertical portion of the justification (Top, Middle, Bottom) is only used for the Put on Drawing report feature. For example, if you select "Top Right" the report is right-justified during the display, printing and when saved to a file (the "top" portion is ignored). If you put the report on the drawing, the report justification is top right.

Available Fields

WIRENO

Wire number

LOC1

"From" device's location code (must end with "1")

CMP1

"From" device's component tag ID (must end with "1")

PIN1

"From" device's wire connection terminal number (must end with "1")

LOC2

"To" device's location code (must end with "2")

CMP2

"To" device's component tag ID (must end with "2")

PIN2

"To" device's wire connection terminal number (must end with "2")

WLAY1

Wire layer "From" device (must end with "1")

WLAY2

Wire layer "To" device (must end with "2")

REF1

Line or grid reference location for "From" device (must end with "1")

REF2

Line or grid reference location for "To" device (must end with "2")

SH1

Sheet assignment for "From" device (must end with "1")

SH2

Sheet assignment for "To" device (must end with "2")

CBL

Cable tag

CBLWC

Cable wire or cable core color

CBLLOC

Cable location attribute value

CBLMFG

Cable Manufacturer attribute value

CBLCAT

Cable catalog part number

CBLASMB

Cable ASSYCODE assignment

CBLDESCCAT

Cable BOM single line description field (pulled from the catalog lookup file for the cable's catalog part number query)

CBLQ1CAT

Cable BOM query1 value (pulled from the catalog lookup file for the cable's catalog part number query)

CBLQ2CAT

Cable BOM query2 value (pulled from the catalog lookup file for the cable's catalog part number query)

CBLMISC1CAT - CBLMISC2CAT

Cable BOM miscellaneous fields (pulled from the catalog lookup file for the cable's catalog part number query)

CBLUSER1CAT - CBLUSER3CAT

Cable BOM user fields (pulled from the catalog lookup file for the cable's catalog part number query)

DESC1CBL-DESC3CBL

Cable description attribute values 1 - 3

CBLP1C2

Cable parent or child (parent = 1, child = 2)

CMP:PIN1

"From" device's component tag and component terminal pin number

CMP:PIN2

"To" device's component tag and component terminal pin number

SEC1

"From" device's drawing section assignment

SUB1

"From" device's drawing sub-section assignment

SEC2

"TO" device's drawing section assignment

SUB2

"TO" device's drawing sub-section assignment

INST1

"From" device's installation code

INST2

"To" device's installation code

IECCMP1

"From" device's IEC tag name (must end with "1")

IECCMP2

"To" device's IEC tag name (must end with "2")

PD1

"From" device's wire connection TERMDESC value (must end with "1")

PD2

"To" device's wire connection TERMDESC value (must end with "2")

SEQ1

"From" device's wire connection sequence value (must end with "1")

SEQ2

"To" device's wire connection sequence value (must end with "2")

PNLWDLEV1

"From" device's panel equivalent level (WDLEV) value (must end with "1")

PNLWDLEV2

"To" device's panel equivalent level (WDLEV) value (must end with "2")

CMPHDL1

"From" device's entity handle value (must end with "1")

CMPHDL2

"To" device's entity handle value (must end with "2")

DWGIX1

"From" device's drawing DWGIX value as listed in FILETIME table of project scratch database (must end with "1")

DWGIX2

"To" device's drawing DWGIX value as listed in FILETIME table of project scratch database (must end with "2")

DWGNAM1

"From" device's drawing properties %D value (must end with "1")

DWGNAM2

"To" device's drawing properties %D value (must end with "2")

CBLHDL

Cable entity's handle value

CBLINST

Cable entity's handle value

CBLDWGIX

Cable's drawing DWGIX value as listed in FILETIME table of project scratch database

WIREHDL1

"From" device's connected wire line entity handle value (must end with "1")

WIREHDL2

"To" device's connected wire line entity handle value (must end with "2")

XDIR1

"From" device's wire connection point direction - i.e. 4 = connects from left (must end with "1")

XDIR2

"To" device's wire connection point direction - i.e. 2 = connects from above (must end with "2")

PNLX1

"From" wire connection's physical X-coordinate value (must end with "1")

PNLY1

"From" wire connection's physical Y-coordinate value (must end with "1")

PNLZ1

"From" wire connection's physical Z-coordinate value (must end with "1")

PNLXDIR1

Panel wire "From" connection point's direction - i.e. 4 = connects from left, 1 = right, 2 = above, 8 = below (must end with "1")

PNLX2

"To" wire connection's physical X-coordinate value (must end with "2")

PNLY2

"To" wire connection's physical Y-coordinate value (must end with "2")

PNLZ2

"To" wire connection's physical Z-coordinate value (must end with "2")

PNLXDIR2

Panel wire "To" connection point's direction - i.e. 4 = connects from left, 1 = right, 2 = above, 8 = below (must end with "2")

CLEN

Panel layout calculated wire length

USER1_1 to USER20_1

"From" device's optional user field

USER1_2 to USER20_2

"To" device's optional user field