To Configure the Value to be Displayed in Standard Balloons
At the Command prompt, enter
AMOPTIONS
.
In the Options dialog box, click the AM:Standards tab.
In the Standard Elements list, double-click Balloon. The BOM Settings dialog box appears.
In the Balloon tab, in the expression box, make the first character an equal sign (=).
In the Category list, select the category of reference to display in the balloon.
From the Select list, select the reference and click
.
Note:
You can combine as many references as required, along with functions and literal text.
Click OK until all dialog boxes close.
Related Concepts
About Setting Up Standard Based Balloons
Related Tasks
To Select the Default Balloon Type
To Set Up the Balloon Size
To Configure Leaders for Balloons
To Configure Text Height and Color for Balloons
To Configure how Balloons are Distributed
Related Reference
Commands for Working with BOMs Balloons and Parts Lists