The Runner Balance Analysis is used to determine the optimum volume for the sections of the runner system. This analysis ensures that the part fills evenly and there is an acceptable pressure magnitude in the cavity, minimizing runner volume.
Runner systems should be balanced to reduce overpacking during the filling phase. During a Runner Balance analysis, the runner system dimensions are altered to ensure that parts fill simultaneously and the volume of the feed system is minimized.
A well-balanced runner system can make considerable savings in material usage. Before performing a Runner Balance analysis, you should check the Fill analysis and ensure that you are satisfied with each of the following: