Temperature profile, cold runner result

The Temperature profile, cold runner result shows the temperature profile from the center of the runner to the surface.

Using this result

The Temperature profile, cold runner result can be created as either an animation plot or an XY plot. When the result is created as an XY plot, the X-axis value of 1.0 represents the surface of the runner and 0 represents the center. The center of the runner will most likely be above the transition temperature because the runner cross section is generally much larger than the part cross section. As a result, the cycle time should be based primarily on temperature profile of the part rather than that of the runner.

Things to look for

Note: Adjustments such as those above, can only be made using a licensed product.