Mesh orientation is important for results accuracy, especially if you run a Cool analysis or run different mold temperatures (top vs bottom) in a filling and packing analysis. Bad mesh orientation on Dual Domain models could cause the reported volume of the part to be wrong.
() to run the automatic mesh orientation command. This command only works for Dual Domain models. You must make sure that there are no mesh defects, such as free edges, non-manifold edges or overlapping elements before running this command. After running the command, if there are remaining orientation problems, you should manually orient elements as described below.
() and then click Show to display the
Mesh Orientation Diagnostic
. There may be individual elements or areas that are not oriented correctly. These will need to be adjusted manually.