The occurrence number property is supported for the following model entities:
- All runner system related entities apart from the sprue (runner, gate, overflow well).
- All part related entities (part, part surface, part beam).
- Preform surface.
- Compression surface.
The occurrence number property is not supported for:
- All Cool analysis related entities (channel, bubbler, baffle, hose, part insert).
- Core (Stress analysis used for core shift prediction does not support occurrence numbers).
Note: Occurrence numbers are supported for Fill+Pack analyses only. If you intend to also run a Cool or Warp analysis, you will need to model all flow paths explicitly.