Fill+Pack Analysis tab dialog

This dialog is used to specify filling phase, packing phase, gate diameter and general solver parameters for the 3D flow solver used in a Fill+Pack or Flow analysis of a 3D model.

To access this dialog, choose an analysis sequence which includes Fill or Fill+Pack (or Flow). Click Process Settings (Home tab > Molding Process Setup panel > Process Settings). Click Next, if necessary, until the Fill or Fill+Pack Settings page appears. Click Advanced Options, then click Edit in the Solver Parameters group. On the Thermoplastics injection molding solver parameters (3D) dialog, select the Fill+Pack Analysis tab.

All solver parameters have a default value that will be suitable for most analyses.

Simulate inertia effect Specify whether you want the effects of inertia to be included in the Navier-Stokes calculation. Selecting this option will improve analysis accuracy for thick parts, but is the most compute-intensive option.
Simulate gravity effect Specify whether you want the effects of gravity to be included in the Navier-Stokes 3D flow simulation calculation.
GPU options Specify whether you want numerical calculations to be performed on a GPU (Graphics Processing Unit) card when running an analysis. The default setting is Automatic; the solver automatically uses the GPU if one is available.
Number of threads for parallelization Specify the number of threads to be used for parallel solution.
Gate contact diameter Set an automatic or specific gate diameter, for use when analyzing your part without a gate(s) or runner system.