Setting up a Gate Location analysis

The following table summarizes the setup tasks required to prepare a Gate Location analysis.

The setup tasks below are for non fiber-filled, or fiber-filled thermoplastic materials.

Setup task Required for analysis technology
Molding processes Midplane Dual Domain 3D
Meshing the model Midplane Dual Domain 3D
Checking the mesh before analysis Midplane Dual Domain 3D
Analysis sequences Midplane Dual Domain 3D
Selecting a material Midplane Dual Domain 3D
Process settings Midplane Dual Domain 3D
Prohibited Gate Nodes
Note: Set prohibited gate nodes when using the Advanced Gate Locator algorithm.
Midplane Dual Domain 3D

Optional setup tasks

Setup task Supported for analysis technology
Injection locations
Note: The Advanced Gate Locator algorithm does not work on models that contain existing gates.
Midplane Dual Domain 3D
Note: You can select between two algorithms when running a Gate Location analysis. If you have not set an injection location for your study, you can use either the Advanced Gate Locator algorithm or Gate Region Locator algorithm. If you have set one or more injection locations, then you can only use the Gate Region Locator algorithm.