The Thermoset Options tab of Reactive Molding solver parameters (3D) dialog is used to specify values for thermoset analysis related inputs for a 3D Reactive Molding analysis.
Viscosity cut-off temperature |
Defines a lower bound for the temperature value when calculating the viscosity of the material. When the predicted temperature of the melt is lower than the cut-off value, then the viscosity is calculated at this viscosity cut-off temperature.
Note: This option is specifically intended for 3D reactive analyses that exhibit convergence problems, typically for materials with a low melt temperature. These convergence problems may be able to be resolved by setting the viscosity cut-off temperature to somewhat higher than the melt temperature.
|